Gray and yellow Sentient Energy logo.
Menu
SOLUTIONS
PRODUCTS
CUSTOMERS
RESOURCES
ABOUT
BLOG
CONTACT
SOLUTIONS

Solutions

Find out how we can help solve your grid challenges.

Learn More

Fault Detection & Location

System Planning

Wildfire Risk Mitigation

Grid Analytics System

Interruption & Disturbance Analysis

Data Source to ADMS Applications

Grid Edge Control™

Proactive Outage Mitigation

Harmonics Measurement

PRODUCTS

Products

Learn more about our intelligent sensors, software applications, and grid edge technologies.

Learn More

Grid Analytics System™

MM3 Overhead Line Sensor

UM3+ Underground Line Sensor

UM1™ Underground Line Sensor

Engineering Services

Ample Analytics Platform

ZM1™️️️ Low Amperage Overhead Line Sensor

ENGO® and GEMS® Grid Edge Voltage Control

MM3ai System

CUSTOMERS

Customer Success

Read about Sentient Energy’s proven client successes, dive into key metrics, and discover how Sentient Energy can help you solve your grid challenges.

Learn More

FPL Automatic Phase Identification

Click here >

Manitoba Hydro Utilizing Line Sensors for Substation Monitoring

Click here >

PG&E Quantifying SAIDI Reduction

Click here >

Feeder Fault Isolation & Restoration

Click here >
RESOURCES

Resources

Explore information on Sentient Energy grid edge solutions, products, use cases, and customer successes. Find valuable insights on distribution grid technology best practices and hear from peers and experts on industry topics that matter.

Learn More

Use Case Briefs

Case Studies

From the Experts

Public Power

White Papers

Product Datasheets

Webinars and Videos

Customer Support Portal

ABOUT

About

Learn more about who we are, what we're focused on, and the leadership team that supports us.

Learn More

Leadership

News

Events

Press

Careers

AWS Partnership

BLOG
CONTACT

Home › Products › MM3 Overhead Line Fault Indicator

OVERHEAD LINE FAULTED CIRCUIT INDICATOR

Increase Visibility of Overhead Power Lines

Sentient Energy’s MM3 is an intelligent overhead power line sensor and faulted circuit indicator with substation-class measurement, computing and processing capabilities. The MM3 is a powerful wireless line sensor designed to be a platform for a set of applications.

Download Data Sheet
Descargar En Espanol
MM3 Sensor.

The MM3 is a foundational element of Sentient Energy’s Grid Analytics System™ which consists of the MM3 and ZM1™ overhead sensors, UM3+™ and UM1™ underground sensors, and the Ample® Analytics Platform. The solution provides utilities with increased distribution system visibility to improve reliability and enable data-driven operational decision making.

MM3 Wireless Power Line Sensor Features

Powerful Sensing

Sensing and measurement capabilities for the MM3 include current, conductor temperature, voltage characteristics, GPS for location, and a precision clock.

Advanced Network Communications

The MM3 supports cellular or mesh communications and is wirelessly configurable, allowing parameters to be easily adjusted as needed. Its software can also be securely upgraded over-the-air to streamline sensor management.

Line Powering

Sentient Energy’s patented power harvesting technology, IBOLT™, generates all the power the MM3 needs from the magnetic field surrounding a conductor carrying 7-10A. This power harvesting eliminates the need for maintenance of batteries and cleaning of sensor solar panels.

Grid Analytics System Applications

Fault Detection & Location

The MM3 wireless power line sensor and faulted circuit indicator uses advanced fault detection algorithms to sense system faults on overhead lines in real-time, communicating fault information immediately to the utility control center for integration with SCADA, DMS or OMS systems. 

With more precise fault location information, operators can dispatch crews to the correct location, significantly reducing patrol time and outage duration.

Bucket of a cherry picker held up to a power line.
3 MM3 Sensors on power lines.

Interruption & Disturbance Analysis

Equipped with high resolution waveform capability at a rate of 130 samples per cycle, the MM3 overhead line sensor captures and records waveforms of faults and line disturbances.

Complete current and E-field waveform data is stored locally on the MM3 and automatically downloads to Ample analytics software.

Distribution Monitoring System

The MM3 Log-I app continually measures current for load monitoring purposes. Collected data is processed on the device and critical information such as alerts, daily peaks, and averages are reported to Ample analytics software.

The MM3 line sensor also senses current direction, which is increasingly important with distributed energy resources, and captures waveform data that allows Ample to validate sensor phase identification.

Screenshot showing load and unbalance.

Contact Sentient Energy

Discover how better visibility means better grid safety and reliability

Contact Us
White and yellow Sentient Energy logo.
  • Products
  • Solutions
  • Public Power
  • Products
  • Solutions
  • Public Power